OET READING · Practice Test 10
OET Reading practice for nurses
This original English Guru Campus test is designed for nurses and allied healthcare professionals preparing for the OET Reading sub-test. It contains 42 questions across three parts: four rapid texts on nasogastric-tube feeding and medicine administration in Part A, six healthcare workplace extracts in Part B, and two analytical articles in Part C. The total time is 60 minutes. Part A is limited to 15 minutes and locks automatically; Parts B and C use the remaining time. On desktop, reading material and questions scroll independently. Mobile devices use a clear stacked layout. Answers, flags and timer deadlines are saved automatically on this device. After submission, you will receive raw and part-wise scores, an approximate scaled score and a complete evidence-based answer review.
Before you begin
Part A: Questions 1–20, 15 minutes. It locks automatically.
Parts B and C: Questions 21–42, using the time remaining from the 60-minute total.
Progress is saved in this browser. The timers start only when you select Start Test.
Text A: Indications, contraindications and placement safety
A nasogastric (NG) tube may be used for short-term enteral nutrition, hydration, medicine delivery or gastric decompression when the gastrointestinal tract is functioning but oral intake is unsafe or inadequate. Before insertion, confirm the clinical indication, prescription and patient identity, explain the procedure and obtain consent. Review the patient for facial or basal-skull trauma, recent upper gastrointestinal surgery, oesophageal obstruction or other factors that may require senior clinical review or an alternative route.
Tube position must be confirmed before the first use and rechecked according to local policy before feeds, water or medicines are given. Acceptable first-line bedside testing uses aspirate obtained from the tube and pH indicator strips intended for human gastric aspirate. Do not use blue litmus paper. If aspirate cannot be obtained, the pH result is outside the approved range, or there is any doubt about position, do not use the tube; request an authorised radiographic check. The radiograph must be interpreted and documented by a clinician assessed as competent to confirm NG-tube position.
Never rely on injecting air and listening over the stomach. Absence of coughing does not prove gastric placement. Recheck position after vomiting, retching, severe coughing, suspected tube movement or any event that could have displaced the tube. Record the external tube length at the nostril and compare it with the documented baseline.
Text B: Pre-feed and administration checklist
| Stage | Required action |
|---|---|
| Before preparation | Confirm the prescription, feed, route, rate and patient identity. Check allergies, fluid restrictions and the expiry date. Perform hand hygiene and use clean equipment. |
| Patient and tube | Position the patient with the head and upper body elevated by at least 30 degrees, unless contraindicated. Confirm tube position by the approved method. Check the external length and fixation; inspect the nostril and surrounding skin. |
| Giving the feed | Use the prescribed delivery method and rate. Do not add medicines directly to the feed. Label prepared equipment according to policy and minimise unnecessary handling of connections. |
| Flushing | Flush with the prescribed volume of water before and after feeding and between separate medicines. Use the water type specified by local policy and the patient’s clinical circumstances. Include flushes in the fluid-balance record. |
| During and after | Keep the patient elevated during feeding and for the prescribed period afterwards. Observe for nausea, vomiting, abdominal distension, pain, diarrhoea, respiratory change or feed leakage. Document the amount delivered, flushes, tolerance and any interruption. |
Text C: Medicines through an enteral tube
Confirm that the enteral route is authorised and that each medicine is suitable for tube administration. Whenever possible, ask a pharmacist to recommend an appropriate liquid or alternative formulation. Liquid preparations are not automatically safe: viscosity, sorbitol content, osmolality and interactions with the tube or feed may matter. Never crush modified-release, enteric-coated, cytotoxic, hazardous or otherwise unsuitable preparations. If suitability is uncertain, stop and obtain pharmacy advice.
- Pause the feed if required for the medicine or its interaction with nutrition.
- Confirm tube position and flush with the prescribed water volume.
- Prepare each medicine separately using clean equipment.
- Give medicines one at a time. Never mix different medicines together in the same syringe.
- Flush between medicines and flush again after the final medicine.
- Restart the feed at the correct time when any required separation period has ended.
Use an enteral syringe that cannot connect to intravenous equipment. Do not force a resistant plunger, as excessive pressure may damage the tube. Record the medicines, water flushes, withheld doses and any problem. If a dose cannot be administered safely, contact the prescriber or pharmacist rather than improvising.
Text D: Intolerance, blockage and escalation protocol
Possible respiratory placement or aspiration: Stop feed or medicine administration immediately if the patient develops sudden coughing, choking, breathlessness, cyanosis, falling oxygen saturation or respiratory distress. Call for urgent clinical assessment, maintain the airway and provide oxygen or emergency support as prescribed. Do not resume use until tube position and the patient’s condition have been reviewed.
Displacement: Stop using the tube if its external length has changed, fixation is loose, the tube is visibly coiled in the mouth, or displacement is suspected after vomiting or retching. Reconfirm position using the approved pathway. Never advance a displaced tube without appropriate authorisation and reassessment.
Blocked tube: Stop the feed. Check for kinks and closed clamps. Attempt gentle flushing with warm water using a large enteral syringe and a push-pause technique. Allow time for the water to act. Do not use excessive force, sharp objects, carbonated drinks or unapproved chemical solutions. If patency is not restored, seek specialist advice and consider tube replacement.
Feeding intolerance: Pause feeding and assess the patient if there is repeated vomiting, increasing abdominal distension, severe abdominal pain or a significant respiratory change. Escalate urgently when symptoms are severe or accompanied by haemodynamic instability. Record the event, actions, volume delivered and clinical response.
Extract 1: Treatment refusal and capacity
A competent adult may refuse a recommended treatment even when clinicians believe the decision carries serious risk. The nurse should first check that the patient has received understandable information about the proposed treatment, material risks, reasonable alternatives and the likely consequences of refusal. Do not treat disagreement as evidence of incapacity. If capacity is uncertain, request an assessment under the organisation’s capacity policy and address reversible barriers such as pain, delirium, communication difficulty or lack of an interpreter. Give the patient time to ask questions and avoid coercive language. Document the information provided, the patient’s stated reasons, questions, decision and the clinicians informed. If the patient changes their mind, reassess consent before proceeding.
Extract 2: Cleaning an isolation room
Clinical staff and environmental-services staff share responsibility for safe isolation-room cleaning, but their tasks are different. Nurses must remove or secure medicines, specimens and confidential papers; discard clinical waste correctly; and identify equipment that requires specialist decontamination. Environmental-services staff clean the room and approved reusable surfaces using the product, concentration and contact time specified for the organism. A room must not be declared ready merely because it looks clean. Following discharge, the isolation sign remains in place until terminal cleaning is completed and documented. Curtains and disposable items are changed when the organism-specific procedure requires it. Any spill of blood or body fluid must be reported promptly so the correct spill procedure can be used.
Extract 3: Malfunctioning infusion pump
When an infusion pump alarms repeatedly, delivers inconsistently, has a damaged casing or fails a safety check, remove it from clinical use. First protect the patient: assess the infusion, check the prescription and establish an appropriate alternative method or replacement device. Do not silence a recurring alarm and continue treatment without identifying its cause. Attach an ‘out of service’ label stating the observed fault, date, ward and reporter’s contact details. Clean the device if safe to do so, but do not dismantle or attempt an unauthorised repair. Send it through the approved medical-engineering pathway and record the asset number. Complete an incident report if the malfunction caused, or could reasonably have caused, patient harm; reporting is required even when staff intervened before injury occurred.
Extract 4: Critical laboratory results by telephone
The laboratory will telephone results classified as critical to an authorised clinician responsible for the patient. The receiver must write the result down, including the patient identifiers, test, value, units, time and caller’s name. The receiver then reads the complete information back; saying ‘yes’ or repeating only the number is not an adequate read-back. Document the notification in the clinical record and inform the responsible prescriber immediately using the escalation route for the area. If that prescriber cannot be reached within the specified timeframe, escalate to the next available senior clinician rather than leaving a voicemail as the only action. The clinician who receives the result remains responsible for ensuring that it is acknowledged and acted on, even if another staff member is asked to make the call.
Extract 5: A confused patient attempting to leave
If a confused inpatient tries to leave the ward, approach calmly, introduce yourself and use short, non-confrontational explanations. Assess immediate risks, possible delirium, pain, unmet needs and the patient’s decision-making capacity for the proposed departure. Do not physically block, restrain or sedate the patient merely because departure appears unwise. Ask a colleague to alert the nurse in charge and medical team while maintaining observation at a safe distance. Use the least restrictive response consistent with immediate safety. If the patient has capacity, staff must respect the decision after explaining risks and arranging the safest practicable discharge. If capacity is lacking, follow the legal and organisational process for urgent best-interest action, document the assessment and involve security only when proportionate to an immediate risk.
Extract 6: Documenting a PRN medicine
Administration of an ‘as required’ (PRN) medicine must be linked to a defined indication, not simply to the time elapsed since the previous dose. Before administration, assess the relevant symptom, check the prescription, maximum dose, minimum interval, allergies, recent administrations and any medicine with the same active ingredient. Record the indication, assessment, dose, route and exact time immediately after giving it. The nurse must then evaluate and document the patient’s response within the timeframe appropriate to the medicine and route. A signature in the medicines chart alone is insufficient. If repeated PRN doses provide poor relief, cause adverse effects or approach the maximum permitted dose, notify the prescriber and request review rather than continuing the same pattern automatically.
When Every Beep Matters: Rethinking Alarm Fatigue
Modern hospital wards speak in electronic tones. Monitors, infusion pumps, ventilators, beds and call systems announce deviations, disconnections and approaching limits. Each signal was introduced for a defensible reason: to draw attention to a patient or device before harm occurs. Yet when hundreds of alarms compete within the same acoustic space, the safety mechanism can begin to undermine itself. “Alarm fatigue” is often described as staff becoming desensitised, but that phrase can sound like an accusation of carelessness. A more useful description is that clinicians are being asked to extract a small number of meaningful warnings from a stream containing many signals that require no action.
Not every non-actionable alarm is technically false. A monitor may correctly detect a brief threshold crossing when a patient moves, coughs or receives routine care. The reading is real, but the alarm does not require intervention. Other alerts are caused by loose sensors, default limits poorly matched to the patient or duplicate devices announcing the same event. Repetition changes behaviour predictably. Staff may widen limits, lower volumes, pause alarms or take longer to investigate because experience has taught them that most signals resolve without action. These adaptations can be rational in the moment, yet collectively they create a dangerous possibility: a genuine warning may resemble the background noise that preceded it.
The usual response is to demand greater vigilance. Posters remind staff never to ignore an alarm, and training emphasises personal responsibility. Vigilance matters, but it is a finite human resource rather than a switch that management can order permanently on. A nurse simultaneously administering medicines, supporting a distressed relative and responding to several monitors cannot give every tone immediate, undivided attention. Treating this as a motivation problem leaves the alarm environment unchanged and may discourage staff from reporting unsafe settings for fear of appearing inattentive.
Reducing the total number of alarms is therefore necessary, but crude reduction is not the goal. Switching devices off or widening thresholds indiscriminately could conceal deterioration. Effective programmes examine which alarms occur, how often they lead to action, how quickly staff respond and whether particular units or devices generate disproportionate noise. Technical teams can repair unreliable sensors and remove duplicate alerts. Clinicians can individualise limits to a patient’s condition within authorised parameters. Short delays may prevent an alarm being triggered by a momentary artefact, although such delays are unsuitable for events where seconds matter. The appropriate design depends on the clinical risk, not on achieving an impressive percentage reduction.
Priority is also communicated badly when devices use similar sounds for events of very different urgency. A low battery, a disconnected monitoring lead and a life-threatening rhythm may all add to the same undifferentiated chorus. Standardised priority levels, distinctive tones and clear visual information can help, but only if staff are trained and the system behaves consistently across devices. Routing selected alerts to handheld devices may reduce corridor noise; it can also create new problems if messages are duplicated, delayed or directed to a nurse who is already occupied. Escalation logic must identify who receives an unanswered alert next, rather than assuming that electronic delivery equals human response.
Alarm management is also a staffing and workflow issue. Data may show that responses slow during handover or when one nurse covers several geographically separated rooms. That finding should trigger redesign, not punishment. Teams need an agreed method for temporarily transferring alarm responsibility during breaks and procedures. Patients and families also require explanation: they may assume every sound represents an emergency, or they may silence a device without understanding its purpose. Inviting them to call staff rather than manipulate equipment turns education into an additional safety layer.
Success cannot be measured by alarm counts alone. A ward could become quieter while serious events are missed. Evaluation should combine alarm frequency with response times, missed-event reviews, clinical outcomes, staff experience and patient perceptions. Near misses deserve particular attention because they reveal how the system behaves before injury occurs. Frontline staff must be involved in reviewing the data; they know which alerts interrupt care without adding information and which quiet changes make them uneasy.
The central lesson is not that alarms are harmful or that clinicians should simply tolerate them better. Alarms are useful when they direct limited attention towards meaningful risk. Hospitals must design the surrounding system so that urgency remains distinguishable. That requires technical maintenance, clinically sensible settings, clear accountability and enough staff to respond. A quieter ward is valuable only when it is also a safer one.
Virtual Nursing: Extra Clinical Capacity or Care at a Distance?
Virtual nursing has moved quickly from pilot project to strategic promise. In a typical model, an experienced nurse works from a remote operations centre and connects to hospital rooms through secure video and audio. The virtual nurse may complete admission histories, reinforce discharge education, perform documentation checks, support less experienced colleagues or observe high-risk processes. Advocates present the model as a way to use scarce expertise across several wards while allowing bedside nurses to spend more time on physical care. The claim is attractive, but its truth depends less on the camera than on how work and accountability are redesigned around it.
Some nursing work transfers readily. A remote nurse can review a medicine list with a patient, confirm that teaching has been understood using teach-back, or contact community services while the bedside nurse manages an unstable patient. Experienced virtual nurses may notice missing information and coach newly qualified colleagues without taking over the encounter. For patients who are comfortable with video, having an additional professional available can feel reassuring. These benefits are most convincing when virtual staff add capacity that the ward genuinely lacked.
However, a video view is not a bedside assessment. It cannot reliably reproduce touch, smell, the full sound of breathing or the subtle impression created when a patient moves. Camera position, lighting, hearing impairment, language barriers and cognitive difficulties further narrow what can be observed. A patient may nod through discharge teaching while a relative outside the frame signals confusion. Virtual nurses therefore need explicit thresholds for requesting in-person review. Confidence becomes unsafe when remote access is mistaken for complete access.
Responsibility can also blur. Suppose a virtual nurse identifies possible deterioration but the bedside nurse is occupied. Who must escalate, who contacts the doctor and who confirms that action occurred? If the answer is merely “the team”, each person may assume someone else has acted. Programmes require named responsibility, closed-loop communication and a backup route when the intended recipient does not respond. Documentation must distinguish what the virtual nurse directly observed from information reported by somebody in the room.
Patient choice is equally important. Consent should be more than a notice stating that video technology is present. Patients need to know when the connection is active, who can see or hear them, whether sessions are recorded and how to request an in-person conversation. The option to decline must be meaningful, particularly during personal care, sensitive discussions or moments of distress. Some patients value the convenience; others experience a screen as intrusive or find it difficult to disclose concerns remotely. A service that labels reluctance as resistance to innovation has misunderstood consent.
The strongest objection arises when virtual nursing is sold primarily as a staffing substitute. Remote support may remove administrative tasks from bedside nurses, but it does not turn, reposition, examine or comfort a patient. If management counts one virtual nurse as a replacement for several ward posts, the remaining nurses may inherit more physical work and interruptions. The technology then redistributes scarcity rather than solving it. Savings may appear on a staffing spreadsheet while falls, delayed care or overtime increase elsewhere. Virtual services need stable funding, technical support and sufficient bedside staffing; otherwise the model becomes an elaborate explanation for vacancy management.
Equity also deserves attention. Patients with limited English, sensory impairment, cognitive impairment or unfamiliarity with technology may benefit least unless interpreting, accessibility and bedside assistance are built in. Hospitals should not exclude these groups from virtual support, nor should they force them into a format that does not work. Staff equity matters too. Virtual roles may enable skilled nurses with disabilities, health limitations or caring responsibilities to remain in practice. Yet organisations must avoid creating a hierarchy in which remote work is viewed either as an easy refuge or as surveillance of bedside colleagues.
Evaluation should ask what changed for patients and staff, not merely how many video calls occurred. Useful measures include delays in admission and discharge work, patient understanding, escalation reliability, bedside workload, safety events, staff retention and differences between patient groups. Qualitative accounts may expose problems that dashboards miss, such as repeated introductions, loss of privacy or contradictory instructions from remote and bedside teams.
Virtual nursing is neither a hollow novelty nor a universal answer. Properly designed, it can extend expertise, share cognitive work and keep experienced nurses connected to practice. Poorly designed, it can fragment responsibility and disguise inadequate staffing. The sensible question is not whether nursing can be delivered through a screen, but which elements can be supported remotely without weakening the relationships, observations and physical presence on which safe nursing still depends.
Your results
Important: The scaled score and grade are approximate study indicators only. OET does not publish a simple official raw-score conversion for independent practice tests.
Expand complete answer review
Question 1
Your answer:
Correct answer:
Explanation: Text A contains this information.
Support: “Absence of coughing does not prove gastric placement.”
Question 2
Your answer:
Correct answer:
Explanation: Text B contains this information.
Support: “head and upper body elevated by at least 30 degrees”
Question 3
Your answer:
Correct answer:
Explanation: Text C contains this information.
Support: “Liquid preparations are not automatically safe”
Question 4
Your answer:
Correct answer:
Explanation: Text D contains this information.
Support: “seek specialist advice and consider tube replacement”
Question 5
Your answer:
Correct answer:
Explanation: Text A contains this information.
Support: “interpreted and documented by a clinician assessed as competent”
Question 6
Your answer:
Correct answer:
Explanation: Text B contains this information.
Support: “Include flushes in the fluid-balance record.”
Question 7
Your answer:
Correct answer:
Explanation: Text D contains this information.
Support: “sudden coughing, choking, breathlessness… falling oxygen saturation”
Question 8
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: radiographic check
Question 9
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: baseline
Question 10
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: 30 degrees
Question 11
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: separately
Question 12
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: enteral syringe
Question 13
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: warm water
Question 14
Your answer:
Correct answer:
Explanation: The missing words are stated directly in the relevant Part A text.
Support: approved pathway
Question 15
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: blue litmus paper
Question 16
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: external tube length
Question 17
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: pharmacist
Question 18
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: push-pause technique
Question 19
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: carbonated drinks
Question 20
Your answer:
Correct answer:
Explanation: The answer is explicitly stated in the Part A guidance.
Support: airway
Question 21
Your answer:
Correct answer:
Explanation: Disagreement alone does not show incapacity; an informed, capable adult may refuse.
Support: “A competent adult may refuse a recommended treatment”
Question 22
Your answer:
Correct answer:
Explanation: Nurses first manage medicines, specimens, papers, waste and specialist equipment.
Support: “remove or secure medicines, specimens and confidential papers”
Question 23
Your answer:
Correct answer:
Explanation: A near miss involving credible potential harm still meets the reporting threshold.
Support: “caused, or could reasonably have caused, patient harm”
Question 24
Your answer:
Correct answer:
Explanation: Delegating the call does not transfer responsibility for follow-through.
Support: “remains responsible for ensuring that it is acknowledged and acted on”
Question 25
Your answer:
Correct answer:
Explanation: The policy prioritises assessment and proportionate, least restrictive action.
Support: “Assess immediate risks… and the patient’s decision-making capacity”
Question 26
Your answer:
Correct answer:
Explanation: The nurse must record whether the medicine achieved its intended effect or caused problems.
Support: “evaluate and document the patient’s response”
Question 27
Your answer:
Correct answer:
Explanation: The writer shifts attention from personal blame to signal overload.
Support: “extract a small number of meaningful warnings from a stream”
Question 28
Your answer:
Correct answer:
Explanation: A reading may be technically correct yet clinically non-actionable.
Support: “The reading is real, but the alarm does not require intervention.”
Question 29
Your answer:
Correct answer:
Explanation: The writer rejects the idea that attention can be commanded without limit.
Support: “cannot give every tone immediate, undivided attention”
Question 30
Your answer:
Correct answer:
Explanation: Reducing counts indiscriminately can remove needed warnings.
Support: “could conceal deterioration”
Question 31
Your answer:
Correct answer:
Explanation: Electronic transmission is not equivalent to confirmed human action.
Support: “assuming that electronic delivery equals human response”
Question 32
Your answer:
Correct answer:
Explanation: The writer treats response delays as system-design evidence.
Support: “That finding should trigger redesign, not punishment.”
Question 33
Your answer:
Correct answer:
Explanation: Near misses expose system behaviour without requiring harm first.
Support: “before injury occurs”
Question 34
Your answer:
Correct answer:
Explanation: The conclusion supports alarms within a properly designed technical and organisational system.
Support: “useful when they direct limited attention towards meaningful risk”
Question 35
Your answer:
Correct answer:
Explanation: Technology alone cannot deliver the claimed benefit; roles and responsibility must change coherently.
Support: “depends less on the camera than on how work and accountability are redesigned”
Question 36
Your answer:
Correct answer:
Explanation: The writer accepts specific benefits under a clear condition.
Support: “most convincing when virtual staff add capacity”
Question 37
Your answer:
Correct answer:
Explanation: The remote view can miss contextual evidence that changes interpretation.
Support: “a relative outside the frame signals confusion”
Question 38
Your answer:
Correct answer:
Explanation: Collective but unnamed responsibility invites diffusion and assumptions.
Support: “each person may assume someone else has acted”
Question 39
Your answer:
Correct answer:
Explanation: Choice is genuine only if refusal is respected in practice.
Support: “how to request an in-person conversation… option to decline”
Question 40
Your answer:
Correct answer:
Explanation: Replacing ward posts with remote support shifts rather than solves the shortage.
Support: “remaining nurses may inherit more physical work and interruptions”
Question 41
Your answer:
Correct answer:
Explanation: The model can widen participation while still creating damaging perceptions if poorly managed.
Support: “enable skilled nurses… to remain in practice… avoid creating a hierarchy”
Question 42
Your answer:
Correct answer:
Explanation: The conclusion is conditional: virtual support has value but cannot erode physical presence, observation and relationships.
Support: “supported remotely without weakening… safe nursing”

Comments
Post a Comment